View Issue Details

IDProjectCategoryView StatusLast Update
0001192T99X171.00 SKB EagleVOCpublic2021-09-30 10:34
Reporter(ALTech) Younkwang Jung Assigned To(SW) Jason LingDue Date
PriorityurgentSeveritys2-severeReproducibilityhave not tried
Status closedResolutionfixed 
Summary0001192: [BFX_AT100][BTF][VoC] the edid was not read correctly
DescriptionHi Kerwin

VoC issues are being reported when the RCU cannot control the TV.
The RCU engineer says that this issue is occurring because the edid was not read correctly.

Already iSet is Ok status : e2[226] is samsung code
04-01 14:40:27.966 4820 4854 E iSet : 01000000e2

checkSum error is occurred after iSet Stop
04-01 14:40:28.034 4820 4854 E iSet : ISET_ERROR_CODE_CHKSUM_ERROR

04-01 14:40:01.918 3453 3453 I SystemControl: Raw EDID
04-01 14:40:01.918 3453 3453 I SystemControl: 00ffffffffffff00 생략.

case "EDID is ok"
00 FF FF FF FF FF FF 00 4C 2D 44 0C 01 00 00 01
2A 18 01 03 80 85 4B 78 0A 23 AD A4 54 4D 99 26..

case "EDID is incorrect"
00 FF FF FF FF FF FF 00 4C 3D 44 0C 01 00 00 01
3A 08 01 03 80 85 4B 78 0A 33 BD B4 44 4D 89 36..

main.log2
EDID ok after repairing
04-01 14:41:21.330 4820 4841 E iSet : 01060000e2 ISET_ERROR_CODE_IDENTICAL_VENDOR
04-01 14:41:21.348 4820 4841 E iSet : Save Edid

Please check attached logs
Thanks
YK.Jung
TagsNo tags attached.
Attach Tags

Users monitoring this issue

User List There are no users monitoring this issue.

Activities

(ALTech) Younkwang Jung

2021-04-06 15:20

developer  

(SW) Kerwin Chen

2021-04-06 20:38

developer   ~0006591

Hi Mr. YK Jung,

We've checked the log files and it maybe solved from iSet APP.
Even EDID is not correct in the beginning, after few minutes we see EDID will be OK.
But this time, iSet doesn't send EDID to RCU because EDID is the same as the one saved in iSet's data.

So the important part is iSet needs to update EDID to RCU again.
Then RCU will have correct TV model for IR code sets.

Thanks !

(ALTech) Younkwang Jung

2021-04-07 09:59

developer   ~0006598

Hi Kerwin

I don't understand what you're saying.
Is STB reading edid information periodically now?

If I look at the flow, it seems that the RCU did not work and did it again after repairing.
It seems that the edid information is updated when repairing.

In my opinion,
1) you need to check why STB can't read it normally.
2) If STB can't read it, STB should try again or try to read it normally.

Thanks!
YK.Jung

(SW) Kerwin Chen

2021-04-07 12:46

developer   ~0006605

Hi Mr. YK Jung,

From the log, I can't tell why it fails to get EDID at the first time.
It maybe TV's issue.
STB read EDID only when hotplug event is received. (HPD is an input pin on STB)
I think user doesn't do HDMI cable so the possible reason to have hotplug event is from TV.

BTW, Jason has a modified version of iSet.
How can you verify ?
Is it possible to update user's FW ?

Thanks !

(ALTech) Younkwang Jung

2021-04-07 14:48

developer   ~0006610

Hi Kerwin

Could you tell me what function Jason modified?
If you give me a detailed explanation, I'll review it. and I'll check the appropriate test.

However, it is not possible to update the user directly.
Thanks!

(SW) Kerwin Chen

2021-04-07 15:35

developer   ~0006615

Hi Mr. YK Jung,

From the log files, RCU doesn't receive correct EDID data so it fails to look up for TV brand.
Problem:
1. iSet store correct EDID in SharePreference, a.xml
2. STB boots up, iSet get EDID with wrong checksum and set it to RCU. RCU response "ISET_ERROR_CODE_CHKSUM_ERROR".
iSet doesn't save this incorrect EDID in SharePreference because checksum error.
3. STB gets correct EDID, iSet compare it with a.xml. iSet ignore to send this EDID to RCU because content is the same.
RCU stays in "ISET_ERROR_CODE_CHKSUM_ERROR"

Solution:
iSet should remove a.xml in SharePreference if there is any error in EDID.

If you need more detail explanation, please contact Brent.
He will help you to understand.
Thanks !

(SW) Jason Ling

2021-04-08 08:57

developer   ~0006625

Hi Mr. Jung

Already fix it in iSet (version 17)

Issue History

Date Modified Username Field Change
2021-04-06 15:20 (ALTech) Younkwang Jung New Issue
2021-04-06 15:20 (ALTech) Younkwang Jung Status new => assigned
2021-04-06 15:20 (ALTech) Younkwang Jung Assigned To => (SW) Kerwin Chen
2021-04-06 15:20 (ALTech) Younkwang Jung File Added: 0130000055_20210402_28_CD_C4_FD_84_C9.zip
2021-04-06 20:38 (SW) Kerwin Chen Note Added: 0006591
2021-04-07 08:54 (SW) Kerwin Chen Assigned To (SW) Kerwin Chen => (SW) Jason Ling
2021-04-07 09:59 (ALTech) Younkwang Jung Note Added: 0006598
2021-04-07 12:46 (SW) Kerwin Chen Note Added: 0006605
2021-04-07 14:48 (ALTech) Younkwang Jung Note Added: 0006610
2021-04-07 15:35 (SW) Kerwin Chen Note Added: 0006615
2021-04-08 08:57 (SW) Jason Ling Status assigned => resolved
2021-04-08 08:57 (SW) Jason Ling Resolution open => fixed
2021-04-08 08:57 (SW) Jason Ling Description Updated View Revisions
2021-04-08 08:57 (SW) Jason Ling Note Added: 0006625
2021-09-30 10:34 (ALTech) Younkwang Jung Status resolved => closed